A gypsum fiber board has a perm rating of approximately 24 to 30 perms depending on thickness and if this board is fastened to a steel deck and the joints and transitions are taped it could be an effective air barrier that allows some drying.
Vapor barrier on roof deck.
Concrete contains a significant amount of moisture and there is no test to.
This can be a problem in any air conditioned enclosure.
Like fully adhered insulation fully adhered vapor barriers need a solid substrate below.
The roof membrane on the top is clearly a vapor barrier.
Everyone knows that water in roof systems is never a positive.
Therefore one will often see it installed directly on a roof deck such as a concrete or wood deck or on a continuous substrate such as gypsum board or wood panels that is installed directly over a metal deck.
The bottom membrane s primary function is that of an air barrier but it s material.
This can be a problem when there is also a vapor barrier on the exterior.
A vapor retarder is commonly installed on the warm interior side of a roof or wall.
But a preinstalled membrane may be even more effective at removing condensation.
This can be a problem in any below grade space.
That means that when we use a vapor retarder in a roof system it s also acting as an air barrier.
Most fully adhered vapor barriers are also air barriers and can serve as a temporary roof during construction.
This method is shown in the image above.
It is therefore suitable for most roofs.
In a low slope roof assembly the vapor retarder is normally installed under the primary roof insulation.
Traditionally we ve insulated the roof panel to try and keep the temperature on the panel from reaching the dew point.
V gard provides an excellent vapor barrier with a vapor resistance value expressed by an sd equivalent air layer thickness of 1 500 m.
This can be a problem where brick is installed over building paper and vapor permeable sheathing.
The midwest roofing contractors association mrca is advising a vapor retarder of less than 0 01 perm is necessary over new concrete roof decks.
Resistant to foot traffic the engineered composition of v gard provides high resistance to static loading and dynamic impact.
A vapor retarder is a material or system that is designed as part of the roof system to substantially reduce the movement of water vapor into the roof system where it can condense.
In fact it is almost a perfect vapor barrier.
Roofs over concrete decks should always have a vapor barrier installed.
The caveat is that the vapor retarder needs to be sealed at all perimeters and penetrations and tied to the wall air barrier so air does not bypass the vapor retarder layer.
From a practical standpoint a vapor retarder of less than 0 01 perm is effectively a vapor barrier almost no moisture passes through to the roof system above.
Typically a vapor retarder has to have a perm rating of 1 0 or less to be successful.
We ll add a vapor barrier so the moist air does not flow up through the insulation and condense on the roof.
And the membrane on the bottom is also a vapor barrier.